SeaDoo RX Instruções de Operação Página 69

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 68
67
Disconnect water OUTLET hose at en-
gine as shown in previous illustration.
Temporarily install a short piece of hose
to replace the one removed.
Antifreeze
Insert a funnel into the temporary hose
and pour antifreeze mix in engine until
the colored solution appears at cooling
system bleed outlet.
At this point, install a hose pincher on
bleed outlet hose.
1. Bleed outlet hose
Continue to pour until antifreeze flows
in engine drain hose.
1. Engine drain hose
Remove pinchers in this order to allow
proper flow of antifreeze.
1. Bleed outlet hose.
2. Air compressor water outlet.
3. Engine cylinder drain hose.
Remove temporary hose and recon-
nect engine water outlet hose.
Remove water regulator valve supply
hose.
1. Water regulator valve
2. Supply hose
Temporarily install a short piece of hose
to replace the one removed.
F07E0LY
F07E0OY
1
F07E0NY
1
F07E0PY
12
smo2000-003B.fm Page 67 Wednesday, November 17, 1999 8:18 AM