Section 08 ELECTRICAL SYSTEM
Sub-Section 03 (CHARGING SYSTEM)
08-03-5
This chart will be useful to find the correct read-
ing.
Battery Storage
Disconnect and remove battery from watercraft.
Check electrolyte level in each cell, add distilled
water up to upper level line.
CAUTION : Do not overfill.
The battery must always be stored in fully
charged condition. If required, charge until specif-
ic gravity of 1.260 is obtained.
CAUTION : Battery electrolyte tempera-
ture must not exceed 50°C (122°F). The
casing should not feel hot.
Clean battery terminals and cable connections us-
ing a wire brush. Apply a light coat of dielectric
grease on terminals.
Clean battery casing and caps using a solution of
baking soda and water.
CAUTION : Do not allow cleaning solution
to enter battery.
Rinse battery with clear water and dry well using
a clean cloth.
Store battery on a wooden shelf in a cool dry
place. Such conditions reduce self-discharging
and keep fluid evaporation to a minimum. Keep
battery away from dew, high moisture and direct
sunlight.
During the storage period, recheck electrolyte lev-
el and specific gravity readings at least every
month. If necessary, keep the battery at its upper
level line and near full charge as possible (trickle
charge).
Activation of a New Battery
WARNING : Never charge or boost bat-
tery while installed in watercraft.
A new battery is factory fresh dry charged. For
storage purposes, it is fitted with a temporary
sealing tube.
CAUTION : Do not remove the sealing
tube or loosen battery caps unless activa-
tion is desired.
In case of accidental premature removal of caps
or sealing tube, battery should be given a full
charge.
Perform the following operations anytime a new
battery is to be installed.
1. Remove the sealing tube from the vent elbow.
WARNING : Failure to remove the sealing
tub could result in an explosion.
2. Remove caps and fill battery to UPPER LEVEL
line with electrolyte (specific gravity : 1.260 at
21°C (70°F)).
NOTE : This battery may fill slower than oth-
ers due to the anti-spill check ball design.
1. Sealing tube removed
2. Battery electrolyte
3. Upper level line
ELECTROLYTE
TEMPERATURE
OPERATION TO PERFORM
°C °F
38
32
27
100
90
80
.012
.008
.004
Add
to the reading
21 70 correct reading
16
10
4
–1
60
50
40
30
004
.008
012
016
Subtract
from the
reading
EXAMPLE NO. 1
Temperature above 21°C (70°F) :
Hydrometer reading : 1.250
Electrolyte temperature : –1°C (30°F)
Subtract .016 Sp. Gr.
Corrected Sp. Gr. is 1.234
EXAMPLE NO. 2
Temperature above 21°C (70°F) :
Hydrometer reading : 1.235
Electrolyte temperature : 38°C (100°F)
Add .012 Sp. Gr.
Corrected Sp. Gr. is 1.247
-
-
-
;
-
;