Section 08 ELECTRICAL SYSTEM
Sub-Section 03 (CHARGING SYSTEM)
08-03-6
3. Allow the battery to stand for 30 minutes MIN-
IMUM so that electrolyte soak through battery
cells.
1. 30 minutes
4. Readjust the electrolyte level to the UPPER
LEVEL line.
1. Battery electrolyte
2. Upper level line
5. Connect a 2 A battery charger for 3 to 5 hours.
Step Connect + lead to battery + post
Step Connect - lead to battery - post
Step Plug battery charger
CAUTION : If charging rate raises higher
than 2.4 A reduce it immediately. If cell
temperature rises higher than 50°C (122°F) or if
the casing feels hot, discontinue charging tem-
porarily or reduce the charging rate.
WARNING : Always charge in a well ven-
tilated area. Keep battery away from ciga-
rettes or open flames. Always turn battery
charger off prior to disconnecting cables.
6. Disconnect battery charger.
Step Unplug battery charger
Step Disconnect - lead
Step Disconnect + lead
7. Test battery state of charge. Use a hydrometer.
1. Specific gravity 1.260
8. If electrolyte level has dropped after charging,
fill with distilled water to UPPER LEVEL line. Af-
ter water is added, continue charging for 1 to 2
hours to mix water with electrolyte.
9. Reinstall caps and clean any electrolyte spillage
using a solution of baking soda and water.
A17E0GA