Section 09 PROPULSION SYSTEM
Sub-Section 01 (JET PUMP)
09-01-22
– Pump must maintain this pressure for at least
10 minutes.
CAUTION : Repair any leak, failure to cor-
rect a leak will lead to premature wear of
pump components.
–NOTE : If there is a pressure drop spray
soapy water around housing cover. If
there are no bubbles, impeller shaft, impeller
shaft seal, or impeller housing is leaking
through porosity and has to be replaced. Jet
pump unit has to be disassembled.
– Disconnect pump gauge tester and remove fit-
ting.
– Check oil level. Refill as necessary.
– Apply Loctite PST 592 to threads of filler plug
then secure it in cover.
JET PUMP SUPPORT
INSTALLATION
HX Model Only
Apply Loctite 598 Ultra Black on support as
shown in the following illustration.
Installation of support is essentially the reverse of
removal procedure.
RIDE SHOE INSTALLATION
Apply Loctite 598 Ultra Black on ride shoe as
shown in the following illustrations.
ALL MODELS EXCEPT HX
1. Apply Loctite 598 Ultra Black as indicated by shaded area
F01J2IA
-
F05J05A
F01J1VA
1
2